Medical Definition of Mach-zender interferometer
1.
This is a variation of the Michelson interferometer which is used mainly in measuring the spatial variation in the refractive index of a gas (or plasma). A Mach-Zender interferometer uses two semi-transparent mirrors and two fully reflective mirrors located at the corners of a rectangle. The incoming beam is split in two at the first semi-transparent mirror, and the two halves of the beam travel along separate paths around the edge of the rectangle, meeting at the opposite corner. Typically one beam is a control, and the other travels through the system under study. The two beams meet at the second semi-transparent mirror, after which they are mixed together and interfere.
(09 Oct 1997)